Shuangyang Building, Yangshe Town, Zhangjiagang City, Jiangsu Province, China.

+86-512 58278339 [email protected]

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000
titanium wires cable cercage wire orthopedic instrument set-0
Home> Products> Titanium Cable Binding System

Titanium Wires Cable Cercage Wire Orthopedic Instrument Set

Medical Device Classification:Class Iii
After-sales Service:Return and Replacement
Brand:shuangyang
Certification:CE,ISO
Material:Stainless Steel
MOQ:1 Set
OEM:Accept OEM
  • Product Description
  • FAQ
  • Related Products

Product Description

Titanium Wires Cable Cercage Wire Orthopedic Instrument Set

图片1.png


The Titanium Wire Cable Fixation Orthopedic Instrument Set represents a unique “flexible internal fixation” system. Instead of relying on rigid steel plates, it achieves circumferential fixation, binding, and tension band stabilization through high-strength titanium alloy cables and precision locking mechanisms. Its core value lies in providing flexible, minimally invasive, and biologically compatible fixation solutions for complex fractures and revision surgeries.

Technical Specifications

Item No.

Product Name

Quantity

50.06.011.00

Straight needle guide

1

50.06.012.00

Curved needle guide

1

50.06.013.00

Beat tool

1

50.06.008.00

Cable guide

1

50.06.010.00

Spicule bender

1

50.06.006.00

Cable cutter

1

50.06.009.00

Spicule cutter

1

50.06.007.00

Flat connector crimper

1

50.06.001.00

Tight cable tool

1

50.06.002.00

Front pressure cable lock Ф 1.3

1

50.06.004.00

Back pressure cable lock Ф 1.3

1

50.06.003.00

Front pressure cable lock Ф 1.8

3

50.06.005.00

Back pressure cable lock Φ 1.8

1

50.06.014.00

Titanium binding system instrument

1

Advantages:

1. Superior biomechanical effects: When applying the ‘tension band principle’ (positioning cables on the tension side of the bone), physiological tension is converted into compressive force at the fracture site, significantly promoting healing. Examples include applications in patella fractures and olecranon fractures.

2. Preservation of Bone Haemodynamics: Compared to bulky plates, slender cables exert minimal pressure and cause less periosteal detachment on bone surfaces, thereby better safeguarding the bone's blood supply and aligning with biological fixation principles.

3. Resolving complex challenges: In stabilising periprosthetic fractures following total hip or knee arthroplasty, cable systems are virtually the standard solution. They securely bind and fixate fracture fragments without compromising the prosthesis itself.

4. Acting as a robust ‘support’: Often employed in conjunction with plates or intramedullary nails, it binds comminuted bone fragments unsecured by plates or anchors long-segment graft bone to the host bone, functioning as a ‘stirrup’ to enhance overall structural stability.

Clinical application scenarios

Application Scenarios:

1. Periprosthetic Fractures

Circumferential fixation for fractures around femoral or tibial prostheses following hip/knee arthroplasty.

2. Augmentation of Comminuted Fractures

Spiral comminuted fractures of the femur, tibia, or humerus, where cable fixation is employed to consolidate bone fragments.

3. Fractures Following the ‘Tension Band’ Principle

Tension band fixation for patella fractures, olecranon fractures, and avulsion fractures of the greater trochanter.

4. Osteotomy and Arthrodesis

Binding fixation of graft bone blocks during spinal correction, ankle arthrodesis, and similar procedures.

5. Bone reconstruction in revision surgery

Following removal of old implants, used to repair bone defects or reinforce fragile cortical bone.

图片2.png图片3.png



The titanium wire cable system is not intended to replace steel plates and screws, but rather serves as a crucial functional supplement and extension to them. Its advantage lies in addressing fixation challenges around prostheses, as well as circular, comminuted, and irregular fractures – issues where steel plates prove difficult to resolve.

Key usage principles: Must be employed with dedicated tensioning devices to apply appropriate and uniform tension (typically with recommended torque values). Insufficient tension may cause fixation failure, while excessive tension risks cable rupture or bone cutting.

FAQ

  • Q: Quality

    A: Our products comply with international regulations and meet the necessary industry certifications. We are also certified to CE,ISO13485, ISO9001 and others. You can view more details of the certifications on the home page of our website.

  • Q: 0rder

    A: shuangyang has a reliable shipping and logistics network to ensure prompt and secure delivery. Our team works closely with reputable carriers to provide efficient shipping services in around 120 countries.

  • Q: OEM/ODM

    A: The minimum order quantity may vary depending on the product and customizationrequirements, Pleasecontact our customer support team for specifc details related to your desired products.

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000